Next-generation EEG headset — EPOC X PRO
Next-generation 16-channel EEG: 24-bit, active amplifiers, Wi-Fi 6. Official Emotiv supplier in Russia: configuration selection, training, and support in Russian.

EPOC X PRO overview: key features
EPOC X PRO is the next generation of wireless Emotiv EEG, created for modern research protocols. The headset retains the proprietary dry sensors with a low preparation threshold but adds 16 channels (parietal P3/P4 added), a 24-bit path with active amplifiers directly on the electrodes, and a selectable sampling frequency of 128/256/512 Hz. Active electrodes reduce impedance noise and motion artifacts—data is cleaner from the first recording, with less time spent on preprocessing.
For mobile and field projects, new communication and memory are critical: the headset transmits data via Bluetooth (hardware support up to version 6.3) and Wi-Fi 6, has onboard memory for over 8 hours of recording at 256 Hz, and timestamp synchronization with approximately 1 ms accuracy. This enables multi-day recordings outside the lab, research in motion, and multimodal protocols with strict timing requirements. Shipments begin under a reservation program—we reserve devices from the first batches for in-demand laboratories.
Six reasons to choose EPOC X PRO
Each feature translates to a specific benefit for your project: from participant preparation speed to data quality and total cost of ownership.
24 bits and active amplifiers
24-bit digitization with preamplifiers on the electrodes provides high signal fidelity: less line noise, fewer motion artifacts, and a higher signal-to-noise ratio — especially important for ERP research and analysis of subtle effects.
16 channels with parietal P3/P4
Extended montage adds P3 and P4—key areas for parietal research: attention, working memory, sensorimotor integration. Other leads follow the standard EPOC X scheme.
Selectable frequency up to 512 Hz
128, 256, or 512 Hz—depending on the project needs. For spectral analysis, 128 is sufficient; for high-frequency activity research and accurate ERPs, use 256–512 Hz (512 Hz is a firmware update).
Wi-Fi 6 and Bluetooth for future-proofing
Two independent transmission channels: Wi-Fi 6 (2.4/5 GHz) for high-bandwidth streams and Bluetooth (tested 5.2, hardware-supported 6.3) for mobile use cases. Low-latency Wi-Fi event markers — via firmware update.
On-board memory 8+ hours
Recording to internal memory solves unsupervised scenarios: multi-day monitoring, research out of coverage area, sports and production. 8+ hours at 256 Hz depending on configuration.
Synchronization accuracy of ~1 ms
Millisecond timestamp alignment is mandatory for multimodal protocols (stimuli, eye-tracker, physiology) and combining data from multiple headsets into one network.
EPOC X PRO use cases
Next-level laboratory research
ERP, spectral analysis, BCI — with signal quality close to wired systems, but without the wires.
Mobile and field EEG
Multi-day recordings in real environments: production, transportation, sports, education — thanks to memory and Wi-Fi/BLE.
Synchronous multi-subject protocols
Group research (hyperscanning) with millisecond synchronization of multiple headsets via a router.
Studies with high timing requirements
Precise event locking to EEG during strict stimulation protocols and multimodal registration.
Transition from EPOC X without changing methodology
Familiar dry sensors and Emotiv software, but 16 channels, 24 bits, and a clean signal — upgrade your equipment without retraining the team.
EPOC X PRO in detail



EPOC X PRO Technical Specifications
| EEG channels | 16: AF3, F7, F3, FC5, T7, P3, P7, O1, O2, P8, P4, T8, FC6, F4, F8, AF4 |
|---|---|
| Sensors | dry EEG electrodes with replaceable tips (flat or comb), active amplifiers |
| Resolution | 24 bits, high signal fidelity |
| Sampling rate | 128 / 256 / 512 Hz (512 Hz — via firmware update) |
| Motion sensor | 9-axis: quaternions 4×16 bits, magnetometer ±4900 µT, accelerometer ±4G; 0/32/64 Hz |
| Bluetooth | hardware support up to 6.3 (verified 5.2) |
| Wi-Fi | Wi-Fi 6 (802.11ax/HE), 2.4 GHz (channel 6) / 5 GHz (channel 44) via router; Wi-Fi Direct — via firmware update |
| Sync accuracy | about 1 ms |
| On-board memory | over 8 hours of recording at 256 Hz (depends on configuration) |
| Battery life | a full research day on a single charge |
| Event markers | low-latency Wi-Fi markers in the EEG stream (firmware update) |
| Software | EmotivPRO and the full Emotiv stack, Cortex API |
| Status | reservation program, supplies — from the first batches |
Software and integrations for EPOC X PRO
The headset works within the Emotiv ecosystem: from ready mobile applications to open API for custom developments.
EmotivPRO
Recording and marking sessions, experimental protocols, exporting raw data; support for 16 channels and 24 bits.
Cortex API / SDK
Software access to EEG, motion, and metrics streams for your own laboratory systems.
Firmware updates
Expanding headset capabilities: 512 Hz, Wi-Fi Direct, low-latency markers — without replacing hardware.
EPOC X PRO in the context of the entire Emotiv lineup
Compare models by channels, sensors, and battery life — or call us, and we'll select a device for your task in 10 minutes.
| Model | Format | Channels | Sensors | Sampling rate | Battery life | Main tasks |
|---|---|---|---|---|---|---|
| MN8 | EEG in-ear earbuds | 2 | Dry, in-ear | internal 256 Hz | up to 6 h | Wellness and mobile applications |
| Insight | Headset headband | 5 | Semi-dry polymer | 128 Hz | up to 20 h | Development, education, BCI prototypes |
| EPOC X | 10–20 cap | 14 | Salt-felt | 128/256 Hz | up to 9 h | Applied research, neuromarketing |
| EPOC X PRO | 10–20 cap | 16 | Dry, active amplifiers | 128/256/512 Hz | workday + 8 hours memory | Next-generation research, field EEG |
| FLEX | Cap + controller | up to 32 | Gel or saline | 256 Hz | up to 6 h | Labs, neurofeedback, multimodal protocols |
Frequently asked questions about EPOC X PRO
What's the difference between EPOC X PRO and EPOC X?
When will EPOC X PRO be available for sale in Russia?
Do active electrodes provide a cleaner signal?
Can recording be done without a computer at all?
Will PRO work for hyperscanning — simultaneous recording of multiple participants?
What warranties and support are available for laboratories?
Ready to implement EPOC X PRO?
We'll send a quote with prices, delivery times, and software configuration for your task — within one business day.